Isco 6700FR Refrigerated Sampler Specifications Ordering Information Refrigerator Height 47 in. 125 cm Width 26 in. 66 cm Depth 26 in. 66 cm Weight (dry) 160 lbs. 73 kg Exterior Materials Resin transfer molded fiberglass with UV resistant fiberglass gel coat Frame Construction Stainless steel Corrosion Protection Condenser Powder coated with polyester Compressor Enamel paint Evaporator Powder coated with food grade epoxy Refrigeration tubing Polyester tubing or phenolic resin Insulation Environmentally safe non CFC foam Top 3 in. 7.6 cm Sides 1.5 in. 3.8 cm Thermal Resistance Factor R-16 Typical Recovery Time 5 minutes Recovery time is defined as the time for the internal air temperature to return to 39°F (4°C) with the refrigerator running and set at 39°F (4°C) and the door has been opened for one minute. The door has been opened at least 4 minutes after the compressor has turned on. External Temperature 75°F 24°C Sample Temperature Set-point Range 32° to 46°F 0° to 8°C Sample Temperature Set-point Accuracy (at 25°C) ±1.8°F ±1°C Refrigerant Type R-134a 1 1 1 2-tetrafluoroethane CH2FCF3 Compressor 1/5 horsepower Power Requirements 120V 60 Hz 240V 50/60 Hz Current Draw Running 3.5 amp @ 120V 1.75 amp @ 240V Starting 17 amp @ 120V 8.5 amp @ 240V Stalled Compressor 21 amp @ 120V 10.5 amp @ 240V Compressor Protection Safety cutout at 221°F 105°C Heaters 3 automatically controlled Heater Capacity 60 watts (evaporator heaters); 30 watts (compressor heater) Software Sample Frequency Selection 1 minute to 99 hours 59 minutes in 1 minute increments Non-uniform times in minutes or clock times 1 to 9999 flow pulses Programmable Sample Volumes 10 to 9990 ml in 1 ml increments Liquid Presence Detector Non contacting patented LD90 Sample Retries If no sample is detected up to 3 attempts; user selectable Rinse Cycles Automatic rinsing of suction line up to 3 rinses for each sample collection Sample Distribution Samples per Bottle 100 maximum Bottles per Sample Up to number of bottles in set Program Storage 3 sampling programs Programming Modes Time non-uniform time flow and STORM Controller Diagnostics Tests for RAM ROM pump display and distributor Controller Weight 11 lbs. 5.9 kg Dimensions 10 x 12.5 x 10 in. 26 x 32 x 25 cm Operational Temperature 32° to 120°F 0° to 49°C Enclosure Rating NEMA 4X 6 IP67 Program Memory Non-volatile ROM Flow Meter 5 to 15 volt DC pulse or 25 millisecond isolated Signal Requirements contact closure Pump Intake Suction Tubing Length 3 to 99 ft. 1 to 30 m Material Vinyl or Teflon Inside Dimension ⅜in. or ¼in. Pump Tubing Life Recommended 500000 pump counts Maximum Suction Lift 26 ft. 7.9 m Typical Repeatability ±10 ml Typical Line Transport Velocity at head heights of: 3 ft. (0.9 m) 2.9 ft./s 0.88 m/s 10 ft. (3.1 m) 2.5 ft./s 0.76 m/s 15 ft. (4.6 m) 1.9 ft./s 0.58 m/s Description Part